MIDDLE CREEK ELEM. SCHOOL

110 MIDDLE CREEK PARK AVE, Apex, NC 27539

Latest facility inspection for MIDDLE CREEK ELEM. SCHOOL in Apex, NC recorded score of 89.5 on March 31, 2025.

Latest result
89.5
Latest inspection score
Last inspection
March 31, 2025
Inspector 1746
Establishment ID
4092440200
Stable state-assigned identifier used for this page.
Violations on latest inspection
5
Summary of the most recent inspection findings available in this dataset.

Recent inspection history

March 31, 2025
Facility inspection
89.5
November 3, 2022
Facility inspection
87
No PDF available

Latest inspection details

Build up and residue is covering the pre-k playground equipment and sunscreen awning. Pressure wash cleaning of this playground equipment and awning is needed.

Latest recorded violations

#3 · -20 demerits · DRINKING FOUNTAINS: Clean and in good repair 40#; adequate pressure, properly regulated 40# (.2406)
Repair nonfunctional drinking fountain in hallway besides entrance of girls bathroom #153.
#4 · -35 demerits · TOILET FACILITIES: Walls and ceilings clean, nonabsorbent, washable, and in good repair 30#; fixtures clean and in good repair 40#; floors impervious, kept clean 30# (.2408)
Repair out of order toilets and urinals in the following student bathrooms: in girls bathroom #153, (one toilet that is in the second to last stall that has poor water flow for flushing), in boys bathroom #226, (one urinal that is at the end of row and has no water flow for flushing), and in classroom bathroom #318A, (one toilet that has poor water flow for flushing and that is leaking on the flush valve). Repair and repaint damaged wall surfaces behind and beside of toilets in the following class and staff bathrooms: in class bathroom #306A, in class bathroom #316A, in class bathroom #320A, in class bathroom #322A, in class bathroom #324A, and in staff bathroom #124. Repair water damaged base of wall and replace loose base tile beneath urinals in the modular building #M824-02 boys bathroom. Repair and seal over halls in the lower stall walls in the modular building girls bathroom #R808-03A.
#5 · -15 demerits · LAVATORY FACILITIES: Fixtures clean and in good repair 30#; soap and individual towels or approved hand-drying devices provided 40# (.2409)
Repair and reattach one faucet that is out of order and loose on the hand wash sink basin at the entrance of boys bathroom #155.
#6 · -15 demerits · FLOORS: WALLS: AND CEILINGS: Floors, walls, and ceilings clean and in good repair 30# (.2410)
Repair the sources of ceiling leaks present in the following school locations: in the gym/multi-purpose room #206 beside the ceiling air conditioning vents, in the ramp corridor room #202A that leads from the gym floor to the stage, and in the hallway adjacent to mechanical room #158. Replace water stained ceiling panels in these leak locations after the sources of the ceiling leaks have been fixed. Reattach loose lower railing to the support post on the front entrance ramp of the modular class building #R808. Priority repairs for safety are needed to prevent possible trip and fall injuries.
#8 · -20 demerits · LIGHTING AND VENTILATION: Fixtures, grills, vents, blinds, drapes, etc., clean and in good repair 40# (.2412)
Repair nonfunctional air conditioning systems in all of the media center #144 rooms and offices. Dust build up and residue is covering the ceiling vents in the gym/multipurpose room #206. A lift is needed to clean these ceiling vents due to the height of the gym ceiling.
Open county violation details